Product name: Head-separated Dual Display Digital Pressure Sensor [For Gas] DPS-400 / DPH-100
Category: Sensors
CONTACTS: 0934.361.799
Details
Thin body controller can do cascade connection and communication with upper devices
|
CE Approved
CE : EMC Directive
Features
Works like a fiber sensor
DPS-400 series accommodates to the requirements for pressure sensors at production site such as miniaturization of sensors for downsizing equipment, convenient shape to fit into machines, and reduction of man-hours when it comes to replacement.
|
|
Current value and threshold value can be checked simultaneously on the dual display
The controller is equipped with a 4-digit dual digital display. Because the threshold value can be adjusted while checking the "current value (current pressure value)", direct setting and checking of the "threshold value" is made smoothly without having to switch screen modes.
|
Wire-saving, space-saving
The quick-connection cables enable reductions in wiring. The connections and man-hours for the relay terminal block setup can be reduced and valuable space is saved. Also, DPS-400 series can be connected side-by-side with fiber sensors FX-300 series or laser sensors LS-400 series.
|
Network communication
Connection to CC-Link open network is possible through the communication unit for CC-Link SC-GU2-C. Monitoring or setting changes can be carried out via a PLC, PC, etc. |
Ultra high-speed response time at 150 μs
Ultra high-speed response time contributes to even greater productivity.
Independent dual outputs and five output modes equipped
The sensor is equipped with two independent comparative outputs in which separate sensing modes can be selected.
(1) EASY mode
This mode is used for comparative output ON / OFF control.
(2) Hysteresis mode
This mode is used for setting comparative output hysteresis to the desired level and for carrying out ON / OFF control.
(3) Window comparator mode
This mode is used for setting comparative output ON or OFF at pressures within the setting range.
(4) Forced output ON mode
The comparative outputs are forcibly maintained at ON irrespective of the set values.
(5) Forced output OFF mode
The comparative outputs are forcibly maintained at OFF irrespective of the set values.
Hexagonal wrench installation saves man-hours and spaces [Industry first*]
Using a hexagonal wrench, obstructions can be avoided and installation can be done easily by turning the bolt from above.
|
Quick maintenance
During maintenance, the sensor head needed to be removed can be easily removed from directly above. |
Mounting shape at 14 mm 0.551 in
Because the dead zone caused by the nut is eliminated, the narrowed-down thickness after installation contributes to space saving. |