logocuoi.png

  • sk
  • sk
    HomeSẢN PHẢMFACTORY AUTOMATIONSEIMENS 〉 Head-separated Dual display Digital Pressure Sensor [For gas & liquid] DPC-L100 / DPH-L100

    ONLINE SUPPORT

    MR. TUNG

    0934 36 1799

    [email protected]

    Head-separated Dual display Digital Pressure Sensor [For gas & liquid] DPC-L100 / DPH-L100
    Head-separated Dual display Digital Pressure Sensor [For gas & liquid] DPC-L100 / DPH-L100
    Lượt xem : 1629

    Product nameHead-separated Dual display Digital Pressure Sensor [For gas & liquid] DPC-L100 / DPH-L100

     

    CategorySensors

     

    c icon4

     

     

    cellphone   CONTACTS0934.361.799

    Liên hệ

    Details

    Powerful and Simple
    High-precision detection of fluid and air pressure

    Head-separated Dual display Digital Pressure Sensor [For gas & liquid] DPC-L100 / DPH-L100
    CE Marking

    CE Approved
    CE : EMC Directive

    Features

    Powerful

    Powerful

    ?All-stainless-steel construction

    ?Suitable for use with a wide range of fluids
    ?Oil-less diaphragm

    All-stainless-steel construction

    ?High-precision pressure control at a system accuracy of within 1% F.S.

    High-precision pressure control at a system accuracy of within 1% F.S.

    ?The sensor head generates analog voltage output, allowing it to be used in a standalone configuration.

    ?Product line

    Product line

    Simple

    Simple

    ?Direct setting of threshold value

    "Current value" and "Threshold value" can be checked at the same time.
    The threshold value can be changed in RUN mode directly.

    Direct setting of threshold value

    3-color display (Red, Green, Orange)

    The main display changes color in line with changes in the status of output ON / OFF operation, and it also changes color while setting is in progress. The sensor status can therefore be understood easily, and operating errors can be reduced.

    3-color display (Red, Green, Orange)

    ?Setting operation mode has a 3-level configuration to suit the frequency of use.

    The setting levels are clearly separated into "RUN mode" for operation settings that are carried out daily, "MENU SETTING mode" for basic settings, and "PRO mode" for special and detailed setting. These make setting operations easy to understand and easy to carry out.

    Setting operation mode has a 3-level configuration to suit the frequency of use.

    Full range of performance and functions in a compact body

    ?1 model to suit a wide variety of applications

    1 model to suit a wide variety of applications

    ?Equipped with independent dual output

    Equipped with two independent comparative outputs, and separate sensing modes can be selected for each of them. Since there are two comparative outputs, one of the comparative outputs can even be used for alarm output. In addition, if an output is not being used, it can be disabled.

    Equipped with independent dual output

    ?Equipped with auto-reference / remote zero-adjustment functions

    If the reference pressure of the device changes, the autoreference function partially shift the comparative output judgment level by the amount that the reference pressure shifts, and the remote zero-adjustment function can reset the display value to zero via external input. These functions are ideal for places where the reference pressure fluctuates wildly, or where fine settings are desired.

    ?Copy function reduces man-hours and human error

    Copy of the setting details for the master sensor can be transmitted as data to the other sensors. If making the same settings for multiple sensors, this prevents setting errors from occurring with the other sensors and also reduces the number of changes required to instruction manuals when equipment designs are changed.

    Copy function reduces man-hours and human error

    ?Energy-saving design! Equipped with an ECO mode

    This mode lowers the display luminance to cut power consumption.

    ?Setting details can be understood at a glance

    The setting details (output, response time and external input, etc.) appear in the digital display. Because the settings are in numeric form that can be easily understood.

    Setting details can be understood at a glance

    ?Power supply cable can be connected with one-touch connection

    The accessory connector attached cable (2 m 6.562 ft) can be connected easily with one-touch connection

    Power supply cable can be connected with one-touch connection

    ?Hold functions

    ?Peak / Bottom hold 1 (standard)

    The peak values and bottom values for fluctuating pressures can be displayed using the dual display.

    Peak / Bottom hold 1 (standard)

    ?Peak / Bottom hold 2 (output-linked) [NEW FEATURE]

    When output turns on (or off), the controller's digital display (current value) is reset and peak / bottom hold operation starts. For example, this functionality could be used to verify the peak pressure for an industrial press each time a workpiece is loaded.

    Peak / Bottom hold 2 (output-linked) [NEW FEATURE]

    ?Current value hold [NEW FEATURE]

    The controller's digital display (current value) is held while external input is on. By activating external input the moment you wish to capture the pressure value, you can pause and verify the display.

    Current value hold [NEW FEATURE]

    ?Tight installation to panels is possible

    An exclusive mounting bracket MS-DP1-2 that is suitable for 1 to 6 mm 0.039 to 0.236 in panel thickness is available.

    Tight installation to panels is possible

    THU DUC TECH Co., Ltd

    Address: : A12/2A  Le Van Viet, Tang Nhon Phu A Ward , 9 District, Ho Chi Minh City

    Phone: 0934 36 1799

    Email: [email protected]

    www.thuductech.com.vn

    0934 361 799