logocuoi.png

  • sk
  • sk
    HomeSẢN PHẢMFACTORY AUTOMATIONSunX - PanasonicSensors 〉 Head-separated Dual Display Digital Pressure Sensor [For Gas] DPH-100 / DPC-100

    ONLINE SUPPORT

    MR. TUNG

    0934 36 1799

    [email protected]

    Head-separated Dual Display Digital Pressure Sensor [For Gas] DPH-100 / DPC-100
    Head-separated Dual Display Digital Pressure Sensor [For Gas] DPH-100 / DPC-100

    Single axis type
    Direct installation using a hexagonal wrench

    Head-separated Dual Display Digital Pressure Sensor DPH-100 / DPC-100
    UL C-UL Recognaized CE Marking

    UL/C-UL , CE Approved
    CE : EMC Directive
    UL : Recognition

    Features

    Breakthrough construction

    Obstructions can be avoided and installation from above can be done much more easily using a hexagonal wrench. This also eliminates wasted installation space and contributes to a smaller installation footprint.

    Breakthrough construction: Hexagonal wrench installation

    Flexible design! Sensor heads can be embedded

    Because the bolts can be turned from directly above, embedding the sensor heads into narrow spaces is possible. In addition, the flat installation leaves no worries for danger of objects striking against the sensor and damaging it.

    Flexible design! Sensor heads can be embedded

    Quick maintenance

    During maintenance, the sensor head needed to be removed can be easily removed from directly above.

    Quick maintenance

    Mounting space-saving

    Space saving during installation.
    Because the dead zone caused by the nut is eliminated, the narrowed-down thickness after installation contributes to space saving.

    Mounting space-saving

    Easy adjustment

    Sensor heads can be turned after installation
    After installation, you can alter the cable direction with the pressure port still secured in place. In addition, the cable does not get twisted during installation.

    Easy adjustment

    Independent use of sensor head possible

    Separate analog voltage output for each sensor head
    The analog voltage output from the sensor head can be picked up directly.

    Independent use of sensor head possible

    Sensor head line-up

    3 types of pressure range

    3 types of pressure range

    Stainless steel pressure ports come in 3 shapes.

    Dual display + Direct setting

    Equipped with a 30 mm 1.181 in square compact-sized dual display.
    "Current value" and "Threshold value" can be checked at the same time.
    The threshold value can be changed in RUN mode directly.

    Dual display + Direct setting

    High-speed response time at 500 μs

    Reduced tact time. Response time contributes to even greater productivity.

    High-speed response time at 500 μs

    The controller's setting operation mode has a 3-level configuration to suit the frequency of use

    The setting levels are clearly separated into "RUN mode" for operation settings that are carried out daily, "MENU SETTING mode" for basic settings, and "PRO mode" for special and detailed setting. These make setting operations easy to understand and easy to carry out.

    The controller's setting operation mode has a 3-level configuration to suit the frequency of use

    3-color display lets you view the controller status at a glance

    The main display color switches between green and red in accordance with the ON / OFF status of output during RUN mode. In addition, the display always appears orange while setting is in progress, so that the status of the controller can be viewed at a glance.

    3-color display lets you view the controller status at a glance

    Copy function reduces man-hours and human error

    Controllers can be connected to a master controller one by one, and a copy of the setting details for the master controller can be transmitted as data to the slave controllers. If making the same settings for multiple controllers, this prevents setting errors from occurring with the other controllers and also reduces the number of changes required to instruction manuals when equipment designs are changed.

    Copy function reduces man-hours and human error

    Sensor head auto-recognition

    The controller will automatically recognize sensor heads when they are connected, even for sensor heads with different rated pressure ranges. There is no need to use the controller to change settings.

    Sensor head auto-recognition

    1 model to suit a wide variety of applications [DPC-100 original functions]

    1 model to suit a wide variety of applications

    Equipped with independent two output and three output modes

    Equipped with two independent comparative outputs, and separate sensing modes can be selected for each of them.
    Two comparative outputs are provided, so that one of the outputs can be used as a warning output. In addition, if an output is not being used, it can be disabled.

    Equipped with auto-reference / remote zero-adjustment functions, More precise pressure management is possible with a minimum of effort

    If the reference pressure of the device changes, the autoreference function partially shift the comparative output judgment level by the amount that the reference pressure shifts, and the remote zero-adjustment function can reset the display value to zero via external input. These functions are ideal for places where the reference pressure fluctuates wildly, or where fine settings are desired.

    Sub display can be customized

    The sub display can be set to indicate any other desired values or letters apart from the threshold value. This eliminates the need for tasks such as affixing a label to the device to indicate the normal pressure value.

    Sub display can be customized

    Setting details can be understood at a glance

    The DPC-100 setting details appear in the digital display.
    Because the settings are in numeric form that can be easily understood, it is useful for times such as when receiving technical support by telephone.

    Setting details can be understood at a glance

    Tight installation to panels is possible

    An exclusive mounting bracket (MS-DP1-2) that is suitable for 1 to 6 mm 0.039 to 0.236 in panel thickness is available.

    Tight installation to panels is possible

    An exclusive mounting bracket (MS-DP1-6) that supports tight installation is available

    Space saving can also be obtained if an L-shaped mounting bracket is used.

    An exclusive mounting bracket (MS-DP1-6) that supports tight installation is available

    Power supply cable can be connected with one-touch connection

    The accessory connector attached cable (2 m 6.562 ft) can be connected easily with one-touch connection.

    Power supply cable can be connected with one-touch connection
    * Options: 5 m 16.404 ft type is also available.

    Types without connector attached cable are also available [DPC-10?-J]

    Commercially-available connectors can be used for cable connections. Only the required length of cable needs to be used, which contributes to a reduced amount of wastage for unneeded cable.

    THU DUC TECH Co., Ltd

    Address: : A12/2A  Le Van Viet, Tang Nhon Phu A Ward , 9 District, Ho Chi Minh City

    Phone: 0934 36 1799

    Email: [email protected]

    www.thuductech.com.vn

     
     