    Ultra-compact sensor head
    A high-functionality intelligent controller

     

    Ultra-compact Laser Collimated Beam Sensor HL-T1
    CE Marking FDA

    CE , FDA Approved
    CE : EMC Directive
    FDA :HL-T?F only

     

    Features

    Ultra-compact sensor head

    The ultra-compact size and yet the high level of performance. These sensors save space.

    HL-T1001A(F) HL-T1005A(F)
    HL-T1010A(F)
    HL-AC1(P)

     

    Resolution of 4 μm 0.157 mil

    A high resolution of 4 μm 0.157 mil (at an average 64 cycles) allows high-precision positioning and size judgment.

    Resolution of 4 μm 0.157 mil

     

    Long sensing range

    Long sensing range of 500 mm 19.685 in [HL-T1005A(F), HL-T1010A(F)] and 2 m 6.562 ft [HL-T1001A(F)] are available.

     

    High-precision judgment even from minute differences in light intensity

    The sensors are sensitive to minute differences in light intensity, so that they can judge even the opacity of glass.
    In addition, the amount of light received can be displayed as a percentage to allow you to determine permeation rates.

    High-precision judgment even from minute differences in light intensity

     

    Minimum sensing object diameter ø8 μm ø0.315 mil [HL-T1001A(F)]

    The laser with a beam diameter of ø1 mm ø0.039 in can sense extremely small objects with dimensions in micrometers such as bonding wires.

    Minimum sensing object diameter ø8 μm <span class=

     

    Adoption of a Class 1 laser

    The adoption of a Class 1 laser (IEC / JIS) eliminates the need for safety countermeasures, so that these sensors can be used in photoelectric sensor applications with confidence.

     

    Fully equipped with convenient functionality

    A wide range of convenient features has been incorporated into the unit's compact body: standard laser beam reception intensity setting / auto scaling setting / measurement processing (various timer and hold functions) / differentiation / monitor focus function.
    These features make the unit useful for a wide variety of applications.

     

    Detection resolution can be easily confirmed

    The current resolution can be easily confirmed by setting the controller to indicate resolution display mode.
    By displaying the resolution, the marginal increment can be easily determined for the threshold value setting, helping to accurately determine whether sensing can be performed.

    Detection resolution can be easily confirmed

    3 types of teaching functions are now available

    3 types of teaching functions are available: positioning teaching / 2-point teaching / automatic teaching, thus enabling a variety of applications to be accommodated for many different types of production sites.

    3 types of teaching functions are now available

     

    Analog output is switchable between current / voltage

    The analog output can be switched between either of two different outputs; current (4 to 20 mA) / voltage (±4 V). With the monitor focus function, the output can be adjusted over the range from -5 V to +5 V, or from 0 V to +5 V, facilitating connectivity with a variety of output devices.

     

    Monitor focus function

    The linear output is fully adjustable over the following range (current: 4 to 20 mA / voltage: ±4 V). The usage of the monitor focus function together with selectable current / voltage switching for the linear output allows for compatibility with a variety of output devices.

    Monitor focus function
    The linear output must be set by determining output values (maximum; current: 0 to 23.5 mA / voltage: ±5.5 V) at two different points, for the arbitrary display value.

     

    FDA regulations conforming types are available

    FDA regulations conforming types, most suitable for equipment used in the USA, are now available.

    - FDA : Class II
    - IEC / JIS : Class 1

     

    Superior operability has been achieved

    All settings can be easily performed by using the fourway keys and viewing the digital displays.

    Superior operability has been achieved

    Calculations for 2 sensors are possible

    The calculation unit (optional) just needs to be connected between the two controllers to enable calculations (addition and subtraction) to be carried out for two sensors. No digital panel controller is needed either.

    Calculations for 2 sensors are possible

     

    Self-check for laser diode deterioration

    The intelligent controller performs self-checking for laser diode deterioration. If the controller detects significant deterioration (end of diode life), an error will be displayed on the main digital display panel. This function enables users to prepare in advance for potential laser diode malfunctions.